Addressable 230V Relay I/O Unit – CMIO353

An extensive range of interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The 230V ac relay unit (CMIO353) enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches.  

Addressable 3 Channel I/O Unit (Reset on Reset) – CIO351

The UL 3 channel I/O unit enables simple interfacing between the fire system and other equipment, such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits, and ground faults.

Addressable 4 Way Mimic Relay Board (4 In, 4 Out) – CIOP4

Eaton's addressable mimic relay boards are 4 and 8-way soft addressing output modules that incorporate integral short circuit isolators. Both relay boards are fully compatible with the current range of Eaton addressable control panels. The units are suitable for switching low voltage (24Vdc at 1A maximum), via a set of non-latching relay contacts. The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers. These triggers are disablement, fault, fire, test panel, test zone pre-alarm, fire routing equipment, fire protection equipment and reset, with up to 16 different trigger sources per output.

Addressable 4-20mA Interface – CGI420

Eaton's 4 to 20mA addressable modules interface with gas detection modules to enable alarms to be reported on Eaton's range of addressable fire alarm system panels. The interfaces have unique addresses on the loop and built-in isolators for loop short circuit protection. Each of the DIL switches JP1, JP2 and JP3 can be programmable to set the threshold level for pre-alarm 1, pre-alarm 2 and alarm respectively. This can be expressed as a percentage of L.E.L (lower explosion limit) or PPM (parts per million).

Addressable 4-Way Sounder Controller – CSC354CPR

Greatly simplifying installation in applications where specialist sounders or beacons are required by avoiding the need to connect them directly to the addressable control panel. Using a single address, each circuit can still be independently controlled according to the required cause and effect programming.

Addressable 8 Way Mimic Relay Board (4 In, 8 Out) – CIOP8

Eaton's addressable mimic relay boards are 4 and 8-way soft addressing output modules that incorporate integral short circuit isolators. Both relay boards are fully compatible with the current range of Eaton addressable control panels. The units are suitable for switching low voltage (24Vdc at 1A maximum), via a set of non-latching relay contacts. The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers. These triggers are disablement, fault, fire, test panel, test zone pre-alarm, fire routing equipment, fire protection equipment and reset, with up to 16 different trigger sources per output

Addressable Micro Single Channel Input Unit – MCIM

Eaton's range of micro interfaces enable the connection of addressable fire alarm systems to fire and non-fire applications such as HVAC control circuits, plant shutdown circuits and sprinkler systems. Included in the range is the micro zone monitor unit, micro single channel output unit and micro single channel input unit. All the units are soft addressed interfaces and incorporate short circuit isolators. The range supports the installation and integration of Eaton's range of addressable fire alarm control panels, providing solutions for most design requirements

Addressable Micro Single Channel Output Unit – MCOM

An extensive range of micro interfaces are available to support our range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Eaton intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Addressable Micro Single Channel Output Unit (Reset on Reset) – MCOM-R

The (MCOM-R) gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors. An extensive range of micro interfaces are available to support our range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Eaton intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Addressable Micro Single Channel Output Unit (Sounder) – MCOM-S

The MCOM-S is identified by the panel as a sounder, and does not reset on silence, resets on reset only. An extensive range of micro interfaces are available to support the Cooper range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Cooper intelligent addressable control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Optional Variants The MCOM-R gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors.

Addressable Micro Zone Monitor Unit – MIU872

An extensive range of micro interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The MIU872 is a single zone input, soft addressed, micro interface, incorporating integral short circuit isolators. It is fully compatible with the current range of Eaton intelligent addressable control panels. It is suitable for interfacing a zone of up to 20 conventional Eaton detectors onto a Eaton intelligent addressable control panel. It will operate with any Eaton conventional detector in configuration with a schottky diode type base (CDBB300).

Addressable Shop Unit Monitor – MSU840

An extensive range of interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The shop monitor unit (MSU840) is designed to enable small units with conventional fire detection to be fully integrated with a main intelligent addressable fire system. This unit is ideal for applications such as connecting individual shop units into a main shopping centre system. An external power supply is required to drive the 2 conventional sounder circuits. This power supply must be regulated for fire and current limited.