Showing 37–48 of 159 results

Show sidebar

Addressable Micro Single Channel Output Unit (Reset on Reset) – MCOM-R

The (MCOM-R) gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors. An extensive range of micro interfaces are available to support our range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Eaton intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Addressable Micro Single Channel Output Unit (Sounder) – MCOM-S

The MCOM-S is identified by the panel as a sounder, and does not reset on silence, resets on reset only. An extensive range of micro interfaces are available to support the Cooper range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Cooper intelligent addressable control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Optional Variants The MCOM-R gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors.

Addressable Micro Zone Monitor Unit – MIU872

An extensive range of micro interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The MIU872 is a single zone input, soft addressed, micro interface, incorporating integral short circuit isolators. It is fully compatible with the current range of Eaton intelligent addressable control panels. It is suitable for interfacing a zone of up to 20 conventional Eaton detectors onto a Eaton intelligent addressable control panel. It will operate with any Eaton conventional detector in configuration with a schottky diode type base (CDBB300).

Addressable Modbus Interface – EC700

The modbus gateway is part of the InfraLINK range of network infrastructure components from partners. All of the modbus gateways feature a robust hardware platform with high performance CPU and UART for fast communications without loss of data. The LonWorks to modbus address mapping is pre-loaded and ready for use with the CF3000 fire system interface board. The EC700 modbus gateway has 3 communications ports for LonWorks, serial and programming connections. The serial port is capable of either RS232 or RS485 (2-wire) communications.

Addressable Multi-Mode Heat Sensor – 400003FIRE-0003X / CAH330

Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor (MAH830 / FXN725) These ranges of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The heat sensor (CAH330) can be set to one of 3 modes 77ºC / 92ºC and rate of rise. These sensors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

Addressable Optical Smoke Sensor – 400002FIRE-0002X / CAP320

Cooper CAP320 Intelligent Addressable Optical Smoke Sensor (MAP820 / FXN723) These ranges of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The optical sensor (CAP320) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Addressable Panel/Interface Programmer – USBINT2

The analogue systems panel Interface is a universal serial bus converter that provides conversions from RS232 to USB, TTL to USB or TTL to RS232. These options provide the connectivity required between a PC and addressable control panels and wireless survey tools. Included in the kit is: USBINT2, driver CDROM, USB cable, RS232 cross-over cable and TTL cable.

Addressable Passive Repeater – CF3000PRG

The CF3000PRG is a cost effective passive repeater panel which can be programmed via its informative display to be either fully passive (display only) or semi passive (restricted system control). When loop connected the repeater panel will display the system information text of the connected control panel and will provide a fire indication, with panel number, of any connected network control panel that has fire activation. The CF3000PRG repeater panel only requires programming with local text information. In addition to the repeater panels main menu driven 2 x 40 backlit LCD display, which provides system status information, it also has 6 supervisory LED’s (power on, alarm, fault, supervisory, test in progress, and scroll).

Addressable Photo-Thermal Sensor – 400004FIRE-0004X / CAPT340

Cooper CAPT340 Intelligent Addressable Photo / Thermal Sensor (MAOH850 / FNX722) This range of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The photo-thermal sensor (CAPT340) will respond quickly to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also raise an alarm at temperatures exceeding 60ºC.

Addressable Reflective Beam Detector 5-50m (Emerging Market) – MAB50R-EM

Two versions of the intelligent addressable loop powered reflective beam detectors are available in this range, the MAB50R-EM with a range of up to 50 metres and the MAB100R-EM with a range of 50 to 100 meters. Both devices are compatible with Eaton’s range of intelligent addressable fire systems. These intelligent addressable loop powered reflective beam detectors are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. These devices are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signaled to the control panel using standard loop wiring so no additional interconnection required.

Addressable Reflective Beam Detector 50-100m (Emerging Market) – MAB100R-EM

Two versions of the intelligent addressable loop powered reflective beam detectors are available in this range, the MAB50R-EM with a range of up to 50 metres and the MAB100R-EM with a range of 50 to 100 meters. Both devices are compatible with Eaton’s range of intelligent addressable fire systems. These intelligent addressable loop powered reflective beam detectors are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. These devices are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signaled to the control panel using standard loop wiring so no additional interconnection required.

Addressable Remote Indicator – MRIAD

The addressed loop connected remote indicator is designed to provide discreet remote indication when a smoke, heat or photo-thermal fire detector that is inaccessible has been activated. Able to monitor multiple detectors within an area thereby minimizing wiring requirements, the remote indicator is connected directly on the loop and is 'soft addressed' by the panel on system startup.