Showing 37–48 of 167 results

Show sidebar

Addressable Manual Call Point (Weatherproof) – MBG817

Two versions of intelligent addressable callpoints are available in this range, the (MBG813) which can be either surface or flush mounted and the (MBG817) which is a weatherproof version. Both the (MBG813) and the (MBG817) are compatible with the Eaton range of intelligent addressable fire systems. These intelligent addressable callpoints are attractively designed, simple to install and are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications.

Addressable Micro Single Channel Input Unit – MCIM

Eaton's range of micro interfaces enable the connection of addressable fire alarm systems to fire and non-fire applications such as HVAC control circuits, plant shutdown circuits and sprinkler systems. Included in the range is the micro zone monitor unit, micro single channel output unit and micro single channel input unit. All the units are soft addressed interfaces and incorporate short circuit isolators. The range supports the installation and integration of Eaton's range of addressable fire alarm control panels, providing solutions for most design requirements

Addressable Micro Single Channel Output Unit – MCOM

An extensive range of micro interfaces are available to support our range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Eaton intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Addressable Micro Single Channel Output Unit (Reset on Reset) – MCOM-R

The (MCOM-R) gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors. An extensive range of micro interfaces are available to support our range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Eaton intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Addressable Micro Single Channel Output Unit (Sounder) – MCOM-S

The MCOM-S is identified by the panel as a sounder, and does not reset on silence, resets on reset only. An extensive range of micro interfaces are available to support the Cooper range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Cooper intelligent addressable control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Optional Variants The MCOM-R gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors.

Addressable Micro Zone Monitor Unit – MIU872

An extensive range of micro interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The MIU872 is a single zone input, soft addressed, micro interface, incorporating integral short circuit isolators. It is fully compatible with the current range of Eaton intelligent addressable control panels. It is suitable for interfacing a zone of up to 20 conventional Eaton detectors onto a Eaton intelligent addressable control panel. It will operate with any Eaton conventional detector in configuration with a schottky diode type base (CDBB300).

Addressable Modbus Interface – EC700

The modbus gateway is part of the InfraLINK range of network infrastructure components from partners. All of the modbus gateways feature a robust hardware platform with high performance CPU and UART for fast communications without loss of data. The LonWorks to modbus address mapping is pre-loaded and ready for use with the CF3000 fire system interface board. The EC700 modbus gateway has 3 communications ports for LonWorks, serial and programming connections. The serial port is capable of either RS232 or RS485 (2-wire) communications.

Addressable Multi-Mode Heat Sensor – 400003FIRE-0003X / CAH330

Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor (MAH830 / FXN725) These ranges of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The heat sensor (CAH330) can be set to one of 3 modes 77ºC / 92ºC and rate of rise. These sensors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

Addressable Optical Smoke Sensor – 400002FIRE-0002X / CAP320

Cooper CAP320 Intelligent Addressable Optical Smoke Sensor (MAP820 / FXN723) These ranges of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The optical sensor (CAP320) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Addressable Optical smoke sensor MAP820

Our addressable range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. We also offer a loop connected remote indicator, designed to offer discreet remote indication and an ability to monitor multiple sensors. This helps to minimise wiring requirements.

Addressable Panel/Interface Programmer – USBINT2

The analogue systems panel Interface is a universal serial bus converter that provides conversions from RS232 to USB, TTL to USB or TTL to RS232. These options provide the connectivity required between a PC and addressable control panels and wireless survey tools. Included in the kit is: USBINT2, driver CDROM, USB cable, RS232 cross-over cable and TTL cable.

Addressable Passive Repeater – CF3000PRG

The CF3000PRG is a cost effective passive repeater panel which can be programmed via its informative display to be either fully passive (display only) or semi passive (restricted system control). When loop connected the repeater panel will display the system information text of the connected control panel and will provide a fire indication, with panel number, of any connected network control panel that has fire activation. The CF3000PRG repeater panel only requires programming with local text information. In addition to the repeater panels main menu driven 2 x 40 backlit LCD display, which provides system status information, it also has 6 supervisory LED’s (power on, alarm, fault, supervisory, test in progress, and scroll).