Order Code | CF1200NC |
---|---|
System | Addressable |
Product Type | Addressable Control Panels |
Addressable 2 Loop Control Panel c/w Network Card, VDS – CF1200NC
The Cooper CF1100/CF1200 range of analogue fire detection panels are available as 1 and 2-loop configured panels. They provide sophisticated ‘touch screen’ functionality yet achieve a simple end user interface operation within a compact panel design.
The CF1100/CF1200 range of panels provide a large (120mm x 90mm) touch screen display as the main user
element, eliminating the need for dedicated system push buttons. The user interface is menu-driven, automatically reconfiguring to suit the chosen menu option. To enable text updates directly at the panel, the display converts to a full QWERTY keyboard, enabling comprehensive text insertion.
The panel also has 16 zone fire LEDs providing additional information about the extent of any fire activation as well as a comprehensive set of system status LEDs providing additional visual information for the end user.
The CF1100/CF1200 range supports a complex cause and effect programming ability which, together with a wide range of user controllable functions, makes the panel suitable for a wide range of projects.
As with all Cooper analogue panels the CF1100/CF1200 range uses ‘spur tolerant’ soft addressing thereby minimizing installation time and removing the potential for errors often associated with other forms of system addressing. As with the entire range of Cooper analogue panels, the CF1100/CF1200 range of panel system components have been specifically designed to operate as part of an integrated system; this provides an assurance that the panel, sensors, interfaces and other ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device
FLEXIBLE
Cause and effect programming
NETWORK CAPABILITY
Up to 126 panels
LARGE ADDRESS LIMIT
Up to 200 addresses per loop
Meets the challenges of small to medium-sized commercial projects
The CF1000 range balances simple of operation, powerful cause and effect programming and competitive pricing. Making it perfectly place for small to medium-sized projects such as offices, industrial premises, schools, universities, care homes and hotels, often to complex for conventional or two-wire systems and not large enough for larger addressable systems.


A trusted system for 13 years
An extensive range of compatible intelligent addressable system ancillaries are available to work with the CF1000 range, all of which incorporate an integral short circuit isolator to provide maximum protection against short circuit faults on the loop. The range of panels have a flexible distributed network capability and full system integrity with Eaton developed protocol.
Features
. Large versatile touch screen display
. 1 and 2-loop panel versions
. Spur tolerant soft addressing
. Short circuit isolators incorporated into every loop device
. Up to 200 addresses per loop
. Network capable with CF3000 and CF2000 rangefully monitored up to 127 panels
. Integral power supply
. Large selection of compatible ancillaries
. Compliant to EN54 parts 2 & 4
1 Loop Panel | CF1100 |
1 Loop Panel c/w Network Card | CF1100NC |
2 Loop Panel | CF1200 |
2 Loop Panel c/w Network Card | CF1200NC |
Standards: | EN54-2 1997 A1: 2006 EN54-4 1997 A1: 2002 A2: 2006 |
Number of loops: | CF1100 : 1 CF1200 : 2 |
Addresses per loop: | 200 |
Number of conventional sounder circuits: | 2 monitored for open and short circuit |
Auxiliary fire routing equipment output (Monitored): | 24V 30 mA (max) |
Auxiliary fault protection equipment output (Monitored): | 24V 30 mA (max) |
Auxiliary fault routing equipment output (Monitored): | 12V 30 mA |
System operating voltage: | 24Vdc (nom) |
Mains input supply: | 230Vac +10%/-15% |
Class change facility: | Terminals for connection of external contacts, can also be instigated via input interface |
Auxiliary Relay: | 1 set of changeover contacts operate in event of fire condition |
Output ports: | RS485, RS232 for connection of repeaters etc. |
Standby duration: | Dependent on loop loading and battery configuration |
Battery: | 2 x 12V 7Ah |
Operating temperature: | -5°C to +40°C |
Humidity (Non-condensing): | 0 to 93% (+2/-3%) RH |
Construction: | Back – Box – Mild Steel Front Door – PC / ABS |
Dimensions (HxWxD): | 375mm x 357mm x 50mm |
Weight (With batteries): | 8kg |
Ingress Protection: | IP30 |
Cable entries: | Top: 11 knockouts (20mm) Rear: 200 x 20mm opening |
System networking: | Fully networkable up to 126 panels (requires additional network card – 1 per panel) |