8 Line Network Exchange Unit – CFVCX8
The VoCALL network exchange unit is a small, wall-mounted unit which can be distributed throughout a site and concealed from view in convenient locations such as risers, stairwells and cupboards.
Ideal for the expansion of Eaton networkable analogue VoCALL systems, with the connection of up to 19 network exchange units possible giving 152 outstations on a network, the exchange unit can greatly reduce the cabling requirement and equipment ‘on view’ in public places such as reception areas. This results in an aesthetically pleasing system for the customer, as well as reducing the costs to install.
Each Network Exchange unit sits on a network and is locally powered with internal battery backup from a monitored, maintained and sealed lead acid battery.
Addressable 230V Relay I/O Unit – CMIO353
An extensive range of interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements.
The 230V ac relay unit (CMIO353) enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems.
The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches.
Addressable 1 Loop Control Panel c/w Network Card, VDS – CF1100NC
The Cooper CF1100/CF1200 range of analogue fire detection panels are available as 1 and 2-loop configured panels. They provide sophisticated ‘touch screen’ functionality yet achieve a simple end user interface operation within a compact panel design.
The CF1100/CF1200 range of panels provide a large (120mm x 90mm) touch screen display as the main user
element, eliminating the need for dedicated system push buttons. The user interface is menu-driven, automatically reconfiguring to suit the chosen menu option. To enable text updates directly at the panel, the display converts to a full QWERTY keyboard, enabling comprehensive text insertion.
The panel also has 16 zone fire LEDs providing additional information about the extent of any fire activation as well as a comprehensive set of system status LEDs providing additional visual information for the end user.
The CF1100/CF1200 range supports a complex cause and effect programming ability which, together with a wide range of user controllable functions, makes the panel suitable for a wide range of projects.
As with all Cooper analogue panels the CF1100/CF1200 range uses ‘spur tolerant’ soft addressing thereby minimizing installation time and removing the potential for errors often associated with other forms of system addressing. As with the entire range of Cooper analogue panels, the CF1100/CF1200 range of panel system components have been specifically designed to operate as part of an integrated system; this provides an assurance that the panel, sensors, interfaces and other ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device
Addressable 1 Loop Control Panel, VDS – CF1100
Eaton's CF1000 range is available as a high specification 1 or 2 loop addressable fire alarm system control panel, offering sophisticated functionality with simple end-user operation through its touchscreen display.
Utilising soft addressing it minimises installation time and removes the potential for errors often associated with manual addressing.
The range can operate as a stand-alone panel or as part of a network with the Eaton range of CF3000 panels or other CF1000 panels (additional network card required). All CF1000 panels include an integral power supply and are supplied with batteries as standard.
Addressable 2 Loop Control Panel – CF30002G
The Cooper CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design.
The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.
The CF3000 uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing. It can operate as a stand alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local.
An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.
Addressable 2 Loop Control Panel c/w Integral Printer – CF30002GP
Cooper CF30002GP Intelligent Addressable 2 Loop Control Panel with Printer (DF60002P / FX60002P)
The Cooper CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.
The CF3000 uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing. It can operate as a stand-alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local. An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.
Addressable 2 Loop Control Panel c/w Integral Printer, Network Card – CF30002GPNC
Cooper Menvier CF30002GPNC Addressable 2 Loop Control Panel c/w Integral Printer, Network Card
Eaton’s CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations.
These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design.
The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.
The CF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. It can operate as a standalone panel or as part of a networked system.
They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local.
An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.
Addressable 2 Loop Control Panel c/w Network Card – CF30002GNC
Cooper CF30002GNC Intelligent Addressable 2 Loop Control Panel with Network Card
The Cooper CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.
The CF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. It can operate as a stand-alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local.
An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.
Addressable 2 Loop Control Panel c/w Network Card, VDS – CF1200NC
The Cooper CF1100/CF1200 range of analogue fire detection panels are available as 1 and 2-loop configured panels. They provide sophisticated ‘touch screen’ functionality yet achieve a simple end user interface operation within a compact panel design.
The CF1100/CF1200 range of panels provide a large (120mm x 90mm) touch screen display as the main user
element, eliminating the need for dedicated system push buttons. The user interface is menu-driven, automatically reconfiguring to suit the chosen menu option. To enable text updates directly at the panel, the display converts to a full QWERTY keyboard, enabling comprehensive text insertion.
The panel also has 16 zone fire LEDs providing additional information about the extent of any fire activation as well as a comprehensive set of system status LEDs providing additional visual information for the end user.
The CF1100/CF1200 range supports a complex cause and effect programming ability which, together with a wide range of user controllable functions, makes the panel suitable for a wide range of projects.
As with all Cooper analogue panels the CF1100/CF1200 range uses ‘spur tolerant’ soft addressing thereby minimizing installation time and removing the potential for errors often associated with other forms of system addressing. As with the entire range of Cooper analogue panels, the CF1100/CF1200 range of panel system components have been specifically designed to operate as part of an integrated system; this provides an assurance that the panel, sensors, interfaces and other ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device
Addressable 2 Loop Control Panel, VDS – CF1200
The CF1100 is a high specification addressable panel for medium sized builds that is equipped with a versatile touch screen user interface. It is available as a 1 (CF1100) or 2 (CF1200) loop panel.
The powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects. The panels can operate as standalone or as part of a network with our other addressable panels (additional network card required).
Addressable 3 Channel I/O Unit (Reset on Reset) – CIO351
The UL 3 channel I/O unit enables simple interfacing between the fire system and other equipment, such as nurse call systems or access control systems.
The inputs are fully monitored for open and short circuits, and ground faults.
Addressable 4 Loop Control Panel – CF30004G
4 Loop card inbuild, each loop with 200 addressable points, Touch Screen Analogue Addressable Fire Panel with 96 Zone display Fire LED's. Requires network card (COFDF61NETKIT) additionally for networking.
Cooper CF30004G Intelligent Addressable 4 Loop Control Panel (DF60004 / FX60004)
The Cooper CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.
The CF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. It can operate as a stand-alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local. An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop