Order Code | CFSFL02 |
---|---|
System | Addressable |
Product Type | Addressable Network and BMS |
Dual Channel Lon to Fibre Optic Adapter – CFSFL02
Eaton has a range of gateways & adapters for LonWorks communication network protocol, for use with Eaton addressable fire systems.
LonWorks adapters (CFSFL01, CFSFL02, EC0232): The CFSFL01 and CFSFL02 allows fibre optic connection to Eaton system network (LonWorks) devices, with the 02 variant extending the system LonWorks up to 15km. The EC0232 Lon to RS232 adapter enables network connection to PC based applications, such as site monitor and site graphics.
LonWorks BMS interfaces (EC200, EC210L): Networked Eaton fire control panels cannot normally be used with a building management system (BMS) where binding is required. The EC200 LonWorks BMS interface is an ‘add-on’ that enables BMS integration. The EC210L should be used with Easicheck panels.
LonWorks network addressable booster (EC540): The Lon Network Booster EC540 will interconnect multiple EIA-709 channels. This unit provides up to five ports and routes packets between these ports.
COMPREHENSIVE
Full range to suit addressable fire system requirements
SOFT ADDRESSING
Helps monitor & manage building management systems (BMS)
USER-FRIENDLY
Easy to install, use and diagnose issues
Benefits
• Extends Cooper network
• Plug and play
• No configuration required
• Simple to use
Plug and play Lon network booster
Used for Eaton network extension, the plug and play installation capability of the EC540 allows network connection without any further configuration. It uses smart switch technology to automatically detect the bit rates of the connected channels,and learn the configuration of the network (domains, subnet / node addresses, group addresses).

Single Mode Lon to Fibre Optic Adaptor | CFSL01 |
Dual Channel Lon to Fibre Optic Adapter | CFSFL02 |
Dual Channel LonWorks BMS Interface | EC210L |
Lon to RS232 Adapter | ECO232 |
Lon to RS232 Adapter (For HMX PA/VA Systems – No Handshake) | EC0232PAVA |
Lon to RS232 Adapter (For HMX PA/VA System – 3 Min Time Delay) | EC0232PAVA3D |
Dual-Channel LonWorks BMS Interface (Non Handshaking) | EC200 |
Dual-Channel LonWorks BMS Interface (Handshaking) | EC200H |
Dual-Channel LonWorks BMS Interface (Self configuring or use with EC700) | EC200S |
Lon Network Booster | E540 |
LONWORKS ADAPTORS
Code: | CFSFL01 | CFSFL02 |
Description: | Single Mode Lon to Fibre Optic Adapter | Dual Channel Lon to Fibre Optic Adaptor |
Operating Voltage: | 24Vdc | 24Vdc |
Communications Protocol: | LonWorks | LonWorks |
LonWorks Connectors: | Screw terminal block | Screw terminal block |
LonWorks Rate: | 78 Kbps / 1.25 Mbps | 78 Kbps / 1.25 Mbps |
Bit Error Rate: | 1.00E-08 | 1.00E-08 |
Wavelength: | 1310nm | 1310nm |
Fibre Type: | Single mode fibre | Single mode fibre |
Fibre Diameter: | 9/125 micron | 9 / 125 micron |
Fibre Connector: | SC type (optional ST type) | SC type (optional ST type) |
Link Distance: | 15km | 15km |
Operating Temperature: | -30°C to +70°C | -30°C to +70°C |
Humidity (Non-condensing): | 20 to 90% RH | 20 to 90% RH |
Dimensions (HxWxD): | 116mm x 136mm x 34mm | 116mm x 136mm x 34mm |
LONWORKS BMS INTERFACES
Code: | EC210L | EC200 / EC200H / EC200S |
Description: | Dual-Channel LonWorks BMS Interface | Dual-Channel LonWorks BMS Interface |
Dimensions (HxWxD): | 86mm x 105mm x 58mm | 86mm x 105mm x 58mm |
Standards: | CE | CE / UL compliant |
Supply Voltage: | 12Vdc to 30Vdc | 12Vdc to 30Vdc |
Supply Current: | <30mA | <30mA |
Transceivers: | Echelon FT5000 / FT-X1 | Echelon FT5000 / FT-X1 |
Baudrate: | 78kbs | 78kbs |
Connectors: | 5mm screw terminals | 5mm screw terminals |
Enclosure: | ABS DIN Rail Mounting | ABS DIN Rail Mounting |
LON NETWORK ADDRESSABLE BOOSTER
Code: | EC540 |
Description: | Lon Network Booster |
Operating Voltage: | 9Vdc to 35Vdc / 9Vac to 24Vac |
Enclosure: | DIN43 880 |
Dimensions (HxWxD): | 60mm x 105mm x 86mm |
Ingress Protection: | IP40 (enclosure) |
IP20 (screw terminals) | |
Installation: | DIN Rail mounting or wall mounting |