Conventional Manual Call Point – CX201, MBG914, FX201

All Cooper conventional call points have integral short circuit isolators and have a status LED fitted as standard. To simplify replacement of glass element call points are fitted with fast fit clip on front covers. Used in the event of a fire or emergency by simply breaking the glass (or plastic) element, the simple to install range of conventional manual call points is compatible with Eaton’s range of conventional fire alarm and notification panels. Two versions are available in the range: indoor and weatherproof. The flush or surface mounted, IP24D indoor option is designed to withstand temperatures between -10°C to +55°C and is best suited to commercial applications such as offices. IP65 rated, the weatherproof variant features a wider operating temperature of -25°C to +70°C and is more suited to industrial applications including warehouses and factories. All conventional call points come complete with a frangible glass element and test key for easy maintenance.

Conventional Manual Call Point (470R/680R Resistor) – 4920016FULL-0018XC

The CX Universal Call Point combines a number of features into one package, simplifying selection and reducing stock variants. Designed to provide the facilities most frequently used, the Universal Call Point is the easy answer for the majority of conventional installations.  

Conventional Manual Call Point (Weatherproof) – CX203

Used in the event of a fire or emergency by simply breaking the glass (or plastic) element, the simple to install range of conventional manual callpoints is compatible with Eaton’s conventional fire alarm and notification panels. There are two versions of the conventional callpoints: the standard internal callpoint (FX201), which can be either flush or surface mounted and the surface mounted weatherproof callpoint (FX203) version. All conventional callpoints come complete with a frangible glass element and test key for ease of maintenance. A comprehensive range of accessories are available to maximize the functionality of the callpoint for particular applications.

Conventional Optical Smoke Sensor – EFXN533

The JSB Cooper EFXN533 conventional optical smoke detector is suitable for most applications giving a fastest response to slow burning or smoldering fires which give rise to large visible smoke particles. The new improved designs have dual PCB connectivity, are LPCB approved and CE marked.

Conventional Optical Smoke Sensor (Value Range) – 400019FIRE-0033X

Typical applications:

Suitable for most applications. Early detection of fire and high immunity against unwanted alarms.

Conventional Photo-Thermal Sensor (Value Range) – 400020FIRE-0034X

Typical applications:

Ideal for both fast-flaming and slow smouldering fires. Dual purpose detector to detect smoke, heat or a combination, supported by high immunity against unwanted alarms.

Conventional Reflective Beam Detector 5-50m – MBD50R

Cooper MBD50R Conventional Reflective Beam Detector - 50m Range The Menvier range of zone powered reflective beam detectors are specifically designed to be compatible with the full range of conventional Menvier control panels. Two versions are available, the MBD50R with a range of up to 50 metres, and the MBD100R with a range of 50 - 100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard zone wiring so no additional interconnection is required. In normal operation only one beam detector may be connected per zone, however special versions are available to work with external power supply if multiple beam detectors are required to be connected to a single zone

Conventional Reflective Beam Detector 50-100m – MBD100R

The Menvier range of zone powered reflective beam detectors are specifically designed to be compatible with the full range of conventional Menvier control panels. Two versions are available, the MBD50R with a range of up to 50 metres, and the MBD100R with a range of 50 – 100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard zone wiring so no additional interconnection is required. In normal operation only one beam detector may be connected per zone, however special versions are available to work with external power supply if multiple beam detectors are required to be connected to a single zone

Conventional Repeater Panel – FXRP2200

JSB FXRP2200 Repeater Panel  To complement the JSB FX2200 range a repeater panel is available for connection to the 4 and 8 zone panels. This repeater has been specifically designed for ease of installation requiring only 2 interconnecting wires from the main panel this compared with up to 16 wires on many conventional panels represents a large cost saving both on material and labour. Further repeater panels can be cascaded. With stand by time not affected by the number of repeaters connected to each panel as each repeater has its own main supply and stand by battery. The repeater is suitable for up to 8 zones and displays all the same functions as the main panel, but with the addition of an indicator test facility.

Conventional Repeater Panel – FXRP2200CF

To complement the FX2200CF range a repeater panel is available for connection to the 4 and 8 zone control panels. This repeater panel (FXRP2200CF) has been specifically designed for ease of installation requiring only 2 interconnecting wires from the main panel this compared with up to 16 wires on many conventional panels represents a large cost saving both on material and labour. Further repeater panels can be cascaded, again only using 2 wires. Standby time is not effected by the number of repeaters connected to each panel as each repeater has its own main supply and stand by battery. The repeater is suitable for up to 8 zones and displays all the same functions as the main panel, but with the addition of a indicator test facility.  

Conventional Sounder (Red Plastic, Shallow Base) FX002SB

This all-purpose sounder has been designed to be both robust and aesthetically pleasing to meet many build requirements. A dependable and proven fire alarm renowned for its durability. Two versions of the low current conventional fire alarm surface sounder are available: the shallow base and the weatherproof deep base. Both are compatible with the Eaton range of conventional fire alarm and notification systems providing clear coverage for emergency evacuation. Out of the box, 32 different alarm tone selections and adjustable volume levels are available via an internal volume controller. Depending on the selected tone, sound levels of up to 105dB(A) can be achieved.

Conventional Sounder Base – MDS824

The conventional base mountable sounder (MDS824/FXN824) has a slim and aesthetically pleasing design and can be installed as either a discreet stand alone sounder or ceiling mounted with a detector and base. The MDS824/FXN824 is compatible with the Eaton range of conventional detectors and fire systems. Mounting with a detector and base simplifies the installation of the system by enabling a detector and sounder to be fixed at a single common point. When used as a stand alone sounder the device can be either wall or ceiling mounted and completed with an optional cover plate (MDS824COV). These conventional base mountable sounders are ideal for applications such as hotel bedrooms where a detector sounder is required.