Addressable Photo-Thermal Sensor – 400004FIRE-0004X / CAPT340

Cooper CAPT340 Intelligent Addressable Photo / Thermal Sensor (MAOH850 / FNX722) This range of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). The photo-thermal sensor (CAPT340) will respond quickly to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also raise an alarm at temperatures exceeding 60ºC.

Addressable Photo-thermal sensor MAOH850

Our addressable range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. We also offer a loop connected remote indicator, designed to offer discreet remote indication and an ability to monitor multiple sensors. This helps to minimise wiring requirements.

Addressable Reflective Beam Detector 5-50m (Emerging Market) – MAB50R-EM

Two versions of the intelligent addressable loop powered reflective beam detectors are available in this range, the MAB50R-EM with a range of up to 50 metres and the MAB100R-EM with a range of 50 to 100 meters. Both devices are compatible with Eaton’s range of intelligent addressable fire systems. These intelligent addressable loop powered reflective beam detectors are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. These devices are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signaled to the control panel using standard loop wiring so no additional interconnection required.

Addressable Reflective Beam Detector 50-100m (Emerging Market) – MAB100R-EM

Two versions of the intelligent addressable loop powered reflective beam detectors are available in this range, the MAB50R-EM with a range of up to 50 metres and the MAB100R-EM with a range of 50 to 100 meters. Both devices are compatible with Eaton’s range of intelligent addressable fire systems. These intelligent addressable loop powered reflective beam detectors are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. These devices are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signaled to the control panel using standard loop wiring so no additional interconnection required.

Addressable Remote Indicator – MRIAD

The addressed loop connected remote indicator is designed to provide discreet remote indication when a smoke, heat or photo-thermal fire detector that is inaccessible has been activated. Able to monitor multiple detectors within an area thereby minimizing wiring requirements, the remote indicator is connected directly on the loop and is 'soft addressed' by the panel on system startup.

Addressable Shop Unit Monitor – MSU840

An extensive range of interfaces are available to support the Eaton range of control panels, providing solutions for most design requirements. The shop monitor unit (MSU840) is designed to enable small units with conventional fire detection to be fully integrated with a main intelligent addressable fire system. This unit is ideal for applications such as connecting individual shop units into a main shopping centre system. An external power supply is required to drive the 2 conventional sounder circuits. This power supply must be regulated for fire and current limited.

Addressable Sounder Base – CAS380

The intelligent addressable sounder base (CAS380) can be used both with a sensor or as a stand alone device. The (CAS380) is compatible with the Cooper range of intelligent addressable sensors and fire systems. This device incorporates a sensor mounting base, a sensor can be fitted to the sounder base or alternatively an optional cover plate (CASC) can be used to enable the sounder to operate as a dedicated discreet stand alone sounder.

Addressable Sounder Beacon Base – CASBB384

The intelligent addressable sounder beacon base (CASBB384) can be used both with a sensor or as a stand alone device. The (CASBB384) is compatible with the Cooper range of intelligent addressable sensors and fire systems. This device includes all the features of the intelligent addressable sounder base (CAS380) whilst also incorporating a powerful LED beacon. The intelligent addressable beacon base incorporates a sensor mounting base, a sensor can be fitted directly to the base, or alternatively an optional cover plate (CASC) can be used to provide a dedicated discreet stand alone device.

Addressable Spur Isolator Unit – CSI350

Eaton's device spur isolator unit enables a spur of addressable devices to be connected to a main analogue loop. Soft addressed, featuring an integral short circuit isolator the device also automatically controls addressing sequence enabling a plug and play installation with no need for hard addressing. The device is designed to simplify installation of remote parts of buildings or for enabling simple system extensions by adding all new devices on one set of wiring to the fire alarm system panel.

Addressable TCP/IP Interface – EC400

The (EC400) is high performance, reliable and secure network infrastructure device for accessing Eaton Lon Network of intelligent addressable control panels over intranet or ethernet. The EC400’s built in configuration server manages up to 256 IP devices on 1 IP channel without a dedicated management PC. This unit supports DHCP even with changing IP addresses in an intranet environment. The easy to understand, diagnostic LED’s allow installers to install and trouble shoot the device without expert knowledge and dedicated troubleshooting tool. To connect the Eaton Lon network via intranet will require a minimum of 2 EC400’s. The first EC400 must be configured as a “configuration server” and the second as a “client” The EC400 when configured as a server requires the address list of all the EC400’s IP addresses in the network.

Addressable Touch Screen Repeater – CTPR3000

The CTPR3000 touch-screen repeater panel provides sophisticated “touch-screen” functionality yet achieves a simple end-user interface operation within a compact panel design. The CTPR3000 is designed to work with all Eaton’s intelligent addressable control panels as well as other network repeaters. Eaton’s touch-screen repeater panel is easy to install and commission. All text is transmitted via the network and is automatically updated.

Addressable Wall Sounder – CAS381

The high efficiency design of these intelligent addressable wall sounders offer excellent sound output levels despite the low current consumption. This device is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation